    Realization of the farad from the dc quantum Hall effect with digitally-assisted impedance bridges

    Full text link
    A new traceability chain for the derivation of the farad from dc quantum Hall effect has been implemented at INRIM. Main components of the chain are two new coaxial transformer bridges: a resistance ratio bridge, and a quadrature bridge, both operating at 1541 Hz. The bridges are energized and controlled with a polyphase direct-digital-synthesizer, which permits to achieve both main and auxiliary equilibria in an automated way; the bridges and do not include any variable inductive divider or variable impedance box. The relative uncertainty in the realization of the farad, at the level of 1000 pF, is estimated to be 64E-9. A first verification of the realization is given by a comparison with the maintained national capacitance standard, where an agreement between measurements within their relative combined uncertainty of 420E-9 is obtained.Comment: 15 pages, 11 figures, 3 table

    Procedure operative per l’utilizzo del sistema criomagnetico Oxford Instrument Teslatron 16T

    No full text
    In this technical report we describe the hardware and software upgrades of the cryomagnetic system Teslatron 16T from Oxford Instruments. Moreover, we give a detailed description of the cooling procedures with some technical data.In questo rapporto tecnico vengono descritte gli aggiornamenti hardware e software implementati sul sistema criomagnetico TESLATRON 16T della Oxford Instruments. Inoltre si dà una descrizione dettagliata delle procedure necessarie al raffreddamento del sistema stesso insieme ad una serie di dati tecnici

    Using spectral analysis and Allan variance to characterise a potentiometric measurement system

    No full text
    To evaluate the noise features of a potentiometric measurement system, low frequency spectral analysis and calculation of the Allan variance have been adopted. This analysis has been applied to the detector alone and then to the whole system under different measurement conditions, to evalutate the low frequency noise contributions of the detector, the Zener devices and the environment

    Analisi sperimentale della conduttivitĂ  longitudinale in dispositivi per effetto Hall quantistico

    No full text
    After a short introduction to the quantum Hall effect, following the model of extended and localised states, the effects of temperature and current on the longitudinal minimum conductivity, as reported by the literature, are discussed. Then the experimental data from two AlGaAs-GaAs heterojunction devices are presented, for several temperatures and currents: T = 2.1÷14.6 K; I = 1÷40 μA. After a short discussion of the current effect, a data processing technique is developed for the temperature data, based on the superposition of the two main transport mechanisms: thermal activation and Variable Range Hopping (VHR). Close to the centre of the minimum of the longitudinal conductivity, thermal activation dominates for higher temperatures and VHR for lower temperatures. Farther from the centre, for all temperatures, the VHR alone explains correctly the experimental data.Dopo una breve introduzione all'effetto Hall quantistico, con particolare riferimento al modello degli stati estesi e degli stati localizzati, si considerano gli effetti, sulla conduttività longitudinale nella zona di minimo, di temperatura e corrente secondo letteratura. Vengono quindi presentate le misure sperimentali effettuate su due dispositivi a eterogiunzione AlGaAs-GaAs, per varie temperature e correnti di misura: T = 2.1÷14.6 K; I = 1÷40 μA. Dopo una breve discussione sull’effetto della corrente, viene sviluppata una tecnica di elaborazione e interpolazione dei dati in temperatura che considera la sovrapposizione dei due principali meccanismi di trasporto: l’attivazione termica e il Variable Range Hopping (VHR). Nell’intorno del centro del minimo di conduttività longitudinale, il meccanismo di attivazione termica domina alle temperature più elevate e il VHR alle temperature più basse. Spostandosi verso i bordi del minimo, a tutte le temperature considerate, il VHR è in grado da solo di interpretare correttamente i dati sperimentali